A study involving a reject film analysis of
rejected radiographs in the X-ray Department of a public teaching
hospital in Benin City was conducted. The objectives of the study
were to: evaluate image quality, determine the reject rate in
conventional radiology procedures and ascertain the causes of
defects on the rejected films. The authors collected rejected films
for a period of three months using a multipurpose-designed data
collection form. Film radiographs collected were sorted out in order
of film sizes and examination types. Six different film sizes were
used during this period and about 36 different X-ray diagnostic
examinations were considered. A total of 8074 X-ray films were
collected during the study period. 719 radiographs were rejected.
Chest radiographs were the most frequently rejected accounting for
(11.7%). The most frequently rejected size was the 24×35cm
accounting for (28.1%). The most frequent cause of film rejects was
due to exposure factor (41.6%).. |